اکستنشن مژه
چسب مژه
خوشهای و نواری
ابزار و بسته بندی
مراقبت و مغناطیسی
همکاری با ما
زبان
نمونه رایگانCures under a UV or LED lamp instead of humidity, so a dry studio and a humid one behave the same. Matched to your lamp wavelength.
Place the fan, check it, then cure.
Removes the variable that changes cyanoacrylate behaviour.
A mismatched lamp under-cures.
| Spec | Value | Note |
|---|---|---|
| Cure | 1 به 2 s under lamp | Matched wavelength |
| Retention | 4 به 6 هفته ها | With aftercare |
| Pack | 5 ml sealed | Batch and expiry |
| Lamp | UV or LED | Tell us which |
MOQ 100 bottles or tubes. Bulk 10 به 15 روزهای کاری پس از واریز. MSDS per lot, batch and expiry printed.
Artists who work at a steady pace and control humidity in the room. Best for salons running six or more sets a day, where the glue has to keep up with the hands.
Beginners still learning isolation, and studios without a hygrometer. A fast glue in a dry room cures before the fan is placed, and the set looks uneven by day three.
Ask for the batch and the production date before ordering a case. Adhesive loses a third of its rated speed after six months in a warm warehouse.
UV adhesive cures when exposed to light in the 365 به 405 nanometre range, not by moisture. That gives the artist control: the glue stays workable until the lamp is applied, so a fan can be positioned precisely and then locked. It also means the bond depends on the lamp reaching the glue line, which is why lamp distance and angle matter more than curing time.
The common failure is under-curing at the base. If the lamp is held too far away, or the lash sits in shadow, the surface sets while the underside stays wet, and the extension releases in the first week. Hold the lamp close, move it along the lash line, and check that the beam covers the base rather than the tips.
Lamp output fades. A tube that has run for a year is not the lamp that was sold, and glue that cured in five seconds when new may need eight. Keep a spare lamp and replace tubes on the manufacturer schedule. UV also needs eye protection for the client, and it is not the right product for a studio that works without a lamp on every station.
No. Without light in the correct range it will not cure, and the set will fail within days.
The lamp requires eye protection. The adhesive itself has less airborne monomer than standard cyanoacrylate, but the exposure is light rather than fume.
Not recommended. The two cure by different mechanisms, and the weaker bond sets the retention for the whole set.
No, the lamp is part of the system.
Tell us wavelength and output; we match the formula.
Four to six weeks.
100 بطری ها.
Through the contact page.
Tell us the cure speed, market and quantity. Quote and sample come back within one working day.